For a Manhattan loft alteration, establish whether the actual units are under Loft Board jurisdiction and obtain the legalization basis before pricing a conversion. A loft's appearance, prior use or marketing description does not establish interim multiple dwelling (IMD) coverage. The owner and its advisers should resolve status; the registered design professional (RDP) should identify the governing design and filing basis.

DOB's [IMD alteration guidance](https://www.nyc.gov/site/buildings/industry/project-requirements-design-professional-alt-loft-law.page) describes legalization as an alteration and identifies Multiple Dwelling Law provisions and, depending on the building and issue, current or prior code provisions. The separate [JLWQA conversion guidance](https://www.nyc.gov/site/buildings/property-or-business-owner/converting-from-jlwqa.page) says an IMD unit within Loft Board jurisdiction is not subject to the SoHo/NoHo JLWQA conversion process it describes.

## Make a legalization register before issuing scope sheets

Use this illustrative register to separate documented facts from open pricing questions. It is not a Loft Board form.

| Record | Evidence to obtain | Preconstruction decision |
| --- | --- | --- |
| Coverage | Registration and unit-specific Loft Board history from owner and advisers | Identify which units and work follow the IMD route |
| Design basis | RDP code analysis, filing history and current issued drawings | Identify applicable requirements without assuming a single code applies to everything |
| Physical work | Issued fire protection, egress, architectural and MEP documents | Assign work and exclusions by package |
| Occupied work | Occupancy and approved protection arrangements | Carry access, temporary services and sequencing by affected area |
| Acceptance | Required inspections, tests and filing closeout identified by RDP | Assign documentation, attendance and correction work |

If records are incomplete, identify the specific unit and the decision owner, and qualify the estimate. Do not present an assumed legalization deadline or eligibility conclusion as an agency determination.

## Translate the issued design into coordinated packages

DOB's guidance identifies egress, sprinkler coverage, mechanical and plumbing work, among other issues, as potentially relevant under different provisions. It does not prescribe the same design for every loft. Ask the RDP to mark the requirements and resolve how the existing conditions affect the issued scope.

For an **illustrative** occupied loft, the issued drawings might show a new protected route and modifications to an existing sprinkler branch. Check who opens and restores ceilings, supports the piping, maintains the occupied route during work and coordinates testing. A sprinkler subcontract that includes pipe but excludes restoration is not necessarily a complete floor-level price. The [fire sprinkler scope review](https://piper-ai.com/resources/fire-sprinkler-scope-assumptions) helps distinguish a design assumption from a documented package boundary.

## Carry the route through occupied work and acceptance

Review unit access and occupied paths with the owner and project team. Where a protection plan applies, carry its actual barriers, temporary services, notices and maintenance into the GC and trade scopes. Sequence shutdowns against the occupied areas and record who obtains access, who restores service and what happens if access is unavailable.

Before bid close, ask the RDP which inspections, tests and final documentation apply to the issued work. Assign inspection readiness, correction work and records to named packages. The [NYC building-code review](https://piper-ai.com/resources/nyc-building-code-preconstruction-review) offers a broader register for code basis and unresolved interpretations; it does not replace the Loft Board's status determination or the project design.