  1. Start with the site and the issued work
  2. Put planning conditions into trade scope
  3. Separate permit issuance from planning review
  4. Build an approval-to-estimate register
  5. Worked example: a commercial renovation with exterior changes
  6. Plan closeout at bid time

For a commercial bid in the City of Albany, treat planning status and building permit status as separate lines in the estimate and schedule. Ask the owner and design team for the actual decisions, approved plans and conditions, then identify who will obtain each remaining approval, pay each fee and carry the work those conditions create. A planning submission or approval is not evidence that a building permit has been issued.

The city's Planning & Zoning portal lists development plan review, variances and certificates of appropriateness among its applications. It explicitly directs general building permit applicants to Buildings & Regulatory Compliance. Which reviews apply, their sequence and their consequences depend on the project. This guide is a bid-review method, not a determination of jurisdiction, code compliance or approval.

Start with the site and the issued work

Confirm the street address and municipality, parcel boundaries, existing use, proposed use, project limits and whether the package includes exterior, site, structural or building systems work. A mailing address alone is not a jurisdiction determination. Ask the owner and architect which authorities have jurisdiction, including any agency beyond the city, and which applications are applicable or already underway.

Request the latest application, decision or approval letter, stamped plans, conditions, correspondence and revision history. Record the document date and scope covered. A decision on an earlier site layout may not resolve a later change to the entrance, equipment screen or parking arrangement. Ask the design team and the city whether revisions require further review; do not assume the answer from a portal status alone.

Put planning conditions into trade scope

Use the city's portal to identify possible planning and zoning applications, then confirm applicability and status with the design team and Planning & Development. The department also links to planning, zoning appeals and historic application case files. A certificate of appropriateness, variance or development plan review is a question to investigate where relevant, not a universal requirement for every alteration.

For each applicable decision, read the conditions against the issued bid drawings. A landscaping condition may affect sitework and planting; a condition on exterior materials may change the envelope package. Identify the drawing revision that incorporates the condition, the trade carrying it and any unresolved design or approval action. If environmental review is relevant, use the separate New York SEQR review to track its status and assumptions; do not assume planning approval proves every environmental question is closed.

Separate permit issuance from planning review

Ask Buildings & Regulatory Compliance which building and trade permits apply to the actual work, who may apply, what submissions are needed and whether there are dependencies on other decisions. The city's Good Neighbor Handbook describes mechanical permit requirements for work including electrical, plumbing, heating and fire suppression systems. Confirm the specific permit and licensing requirements with the city rather than treating that general guidance as a complete permit list.

The city's construction permit records portal can show permit status, inspector and permitted work. Match the record to the address, scope and current plans, and obtain the underlying permit and conditions. The city says work cannot start until the permit has been approved and issued in its building department FAQ. Confirm the permitted start and any project-specific sequencing with the department.

An applicant, a fee payer and the trade performing work can be different parties. Review the contract and trade bids before assigning those roles. Also distinguish contractor credentials and project permits: a subcontractor's qualification does not establish that the project has the approvals needed for its work.

Build an approval-to-estimate register

Use one row per decision or permit and retain links to the evidence. The entries below are prompts, not a statement that every approval applies.

Decision or milestoneEvidence and owner to confirmEstimate and schedule treatment
Planning or zoning reviewApplicability, decision, conditions and responsible applicantCarry condition-driven work; show remaining submission and decision dependencies
Historic review if applicableScope covered, decision and approved exterior detailsPrice approved materials and lead times; flag unresolved design changes
Building permitApplication and issued permit, plan revision, applicant and fee payerCarry preparation and fees as assigned; place issuance before affected work
Trade permits and inspectionsRequired permits, eligible applicants, inspection and test responsibilitiesLevel trade exclusions; carry fees, coordination and return visits as contractually assigned
Occupancy or closeout if applicableRequired submissions, inspection and responsible permit holderAssign as-builts, certifications and fees; show predecessor activities before occupancy milestone

Add columns for status as of a date, source or case number, accountable person, next action, due date, budget basis and effect on the critical path. Use statuses such as not yet confirmed, application submitted, decision issued with conditions and permit issued. A blank is not a no. For each unresolved item, issue a specific RFI before the bid deadline: identify the document, decision needed, requested answer date and the cost or schedule assumption if no answer arrives. State qualifications only as permitted by the solicitation.

Separate application effort, municipal fees, design revisions, construction work, inspections and delay exposure. Do not hide all of them in a single permit allowance. If a subcontractor excludes fees or inspection attendance, show the add-back or assign it elsewhere before carrying the price. If the owner retains application responsibility, the GC may still need to carry coordination or work required by the issued conditions; check the contract.

Worked example: a commercial renovation with exterior changes

In this illustrative hard-bid renovation, the drawings show an entrance alteration, new rooftop equipment and associated electrical work. The owner says the design has been submitted for planning review, but the bid package contains no decision or conditions. The estimator does not mark planning complete. The register assigns the owner and architect to provide the current submission, decision and conditions, and asks Planning & Development whether further zoning or historic review applies to the proposed work.

The GC separately asks Buildings & Regulatory Compliance to confirm the building and trade permits, applicants, fees and inspection requirements. The electrical bid includes installation but excludes permit fees; the estimator records the exclusion and either carries a supported add-back or assigns the fee to another party under the bid documents. The schedule shows a permit issuance milestone before affected work, with the duration identified as an assumption pending the city's project-specific guidance.

If an approval condition changes the equipment screen or entrance details, the GC prices the revised issued scope and checks its effect on steel, roofing, electrical connections and lead times. The team also reviews accessibility in renovation bids with the design team rather than inferring the design requirements from the approval register. An unanswered condition remains an explicit bid question, not a concealed zero-dollar carry.

Plan closeout at bid time

For projects requiring a certificate of occupancy, the city states that the permit holder supplies required materials to the inspector to close the permit and obtain the certificate. Its construction certificate of occupancy guidance identifies submissions including professional certification and as-built information, with other items depending on the project. Confirm the applicable list, fee and inspection sequence with the city and allocate preparation and collection in the contract and schedule.

Before bid submission, give the project team the register with its evidence, open RFIs, allowances and exclusions. Update it when an addendum, decision or issued permit changes the scope. The owner, design professionals and authorities remain responsible for their respective determinations; the estimator's deliverable is a traceable cost and schedule basis.