  1. Psychiatric center EOI and reference plans
  2. Air-handling units and controls interfaces
  3. Qualification and final bid documents
  4. Turn the issued scope into a trade review

DASNY solicitation 383130 concerns replacement of 11 air-handling units in Buildings 1 and 2 at Brooklyn Children’s Psychiatric Center, 1819 Bergen Street, Brooklyn. The project title also identifies controls. The immediate decision for a GC is whether to qualify a team capable of coordinating the unit replacements, not how to submit a final construction price. DASNY official opportunity: OMH Brooklyn Children’s Psychiatric Center Replace Air Handling Units and Controls at Buildings 1 and 2

This is independent Piper analysis, not an agency notice. Source information was checked November 15, 2026; verify the current agency documents before acting.

Psychiatric center EOI and reference plans

The November 5, 2026 notice is an expression of interest only, due December 3 at 2 p.m. DASNY will evaluate qualification packages and invite qualified firms to bid. Its posted drawings and specifications are reference material and do not represent 100% construction or bid documents. Final documents are to go to invited firms.

Sources for this project: DASNY official opportunity: OMH Brooklyn Children’s Psychiatric Center Replace Air Handling Units and Controls at Buildings 1 and 2.

Air-handling units and controls interfaces

Use the reference material to map each unit to its building, access and removal route, duct and piping connections, electrical feeds and controls. For each interface, identify the likely trade and the drawing or specification that must confirm the boundary. Ask what temporary service and shutdown windows the final documents require and how controls integration and testing will be divided. These are estimating questions, not requirements established by the notice.

Qualification and final bid documents

The ten-tab EOI requests five years of similar experience, five relevant projects from the last ten years, three sample schedules, safety and team information, potential subcontractors, workload, EMR, bonding and vendor responsibility information. DASNY says it scores tabs 1 through 7. The notice states a project PLA and lists anticipated participation goals, with final EEO and M/WBE goals to be determined with the final bid documents. Confirm receipt as required in the notice.

Turn the issued scope into a trade review

Once the team has the issued documents, use the construction scope review guide to assign inclusions, exclusions and unresolved interfaces. The NYC public bid review checklist helps check notice obligations separately. Compare the named package with the NYC public project directory before reusing assumptions from another job.