Landmark window bids: compare the approved opening and profile, not just the unit count

Level landmark window bids by opening, facade classification, historic profile, finish and approved repair or replacement detail.

Guide1 min read

Published

Construction scaffolding interior

Bring a current or completed project and see how Piper saves review time, surfaces scope gaps, and applies your company's knowledge.

Book a demo
On this page
  1. Build the window-type register
  2. Example: two quotes, one window schedule

For a designated Manhattan building, a unit count alone does not establish a comparable window bid. Classify the facade, identify the historic and existing window, and match each proposed repair or replacement to the reviewed detail.

Build the window-type register

LPC's windows and doors guide distinguishes primary, visible secondary and non-visible secondary facades. Dimensions, operation, material, finish and documented exceptions affect the review. The applicable criteria and approved drawings must be checked for each project; visibility alone does not authorize a particular replacement.

Register fieldEvidence to requestBid-leveling consequence
Location and facadeElevation, opening identifier and visibilitySeparate different review conditions
Existing conditionSurvey and photos, with repair assessmentState repair or replacement assumption
ConfigurationOperation, glazing proportions and dimensionsCompare like window types
Detail and finishComparative sections, material and colorExpose profile or finish exclusions
ReleaseApproved type and applicable variationHold fabrication of unresolved types

A conditions assessment and comparative details can support certain replacement applications. Repair or retrofit may be an alternative, and an approved master plan may define repeated work. Obtain the actual documents before describing either as the project's decision.

Example: two quotes, one window schedule

An illustrative bid has one quote for all openings and another separating a street-facing type from a rear type. Ask both vendors to identify opening IDs, operation, sections, finish, perimeter treatment and access. Carry surveys and any unapproved exceptions separately. The lower total is not comparable if it omits historic profile matching or assumes replacement where the issued scope calls for repair.

Tie access and facade work to Local Law 11 facade scope, and normalize subcontractor exclusions before buyout.